G1701DA
Revision D.03.00 SP1
D.03.00 SP1 is a Service Patch to the D.03.00 revision of the software.
D.03.00 SP1 fully supports the new ICC
firmware for the CTC control.
Six (6) software defects which were
documented in the PVCS has been fixed
with this service
pack 1 release.
========================================================================
G1701DA
Revision D.03.00
CONTENTS
1. New Features
1.1 Hardware
1.2 SemiQuant
1.3 Instrument Control Enhancements
1.4 Data Analysis Enhancements
1.5 Enhanced Data Analysis Tools
2. Compatibility
3. Instruments Supported
4. Instruments Not Supported
5. Software Supported
6. Software Not Supported
1.
New Features
This
revision adds numerous features to the G1701DA MSD Productivity ChemStation.
1.1
Hardware
Support
for the new 5975B VL MSD (diffusion pump).
Support
for the CTC PAL autosampler (available for Enhanced, DrugQuant, and
EnviroQuant modes of operation only).
1.2
SemiQuant
(Fully
supported in Enhanced and Aromatics modes only)
A
SemiQuant quantitation type has been added to the quantitation parameters
allowing estimation of uncalibrated compound concentration based on a
calibrated compound or internal standard.
A
new menu item is available via the Calibrate menu and allows conversion
of
target compounds into SemiQuant compounds.
This facilitates conversion
from a normal or RTL method into a SemiQuant method.
Another
new menu item is available via the Calibrate menu that allows
response factor updates of SemiQuant compounds.
SemiQuant
reports are available to handle the SemiQuant compounds separately
from target compounds to reduce ambiguity within reports.
1.3
Instrument Control Enhancements
High
performance SIM/Scan functionality is now available for the 5975B
Series MSDs. The MSDs can
now utilize 1 millisecond SIM dwell times for SIM
and
SIM/Scan modes of operation.
Integrated
control for the CTC PAL autosampler (with G3384AA add-on CTC
Control
software).
1.4
Data Analysis Enhancements
Easy
Extracted Ion Chromatograms (Easy EICS) allows the user to add an EIC
of
single ion value or mass range to the chromatogram window by using the
mouse, and the ability to simultaneously display up to 3 separate
spectrum
windows. Other features include the ability to save multiple EIC
specification lists for later recall, and the ability to run a
multiple
spectra PBM or NIST search. The Easy EIC functions also run in Overlay
Chromatogram
view permitting display of multiple EICs and up to 3 spectra
for
every data file selected.
The
AutoSIM setup feature in Data Analysis has been updated to allow
automatic generation of a SIM, Scan, or SIM/Scan acquisition method from
an
existing method having a quantitation database.
The
Update Calibration dialog has been revised to allow update of mass
assignments.
The
Snapshot feature can now display data being acquired during a SIM, Scan,
or
SIM/Scan run.
A
Reprocessing menu is available that allows a previously run sequence to be
reprocessed inside of Data Analysis. A sequence may be reprocessed with an
edited Sample Log Table, such as one containing different sample
amounts.
1.5
Enhanced Data Analysis Tools
(Available
in Enhanced mode for MS data only)
The
Analyze Multiple Data Files view can be used to compare the integrity of
samples over time or from different equipment. The view is primarily for
qualitative investigation of groups of data files. All of the normal
functions needed to process data files are available plus additional
functions such as splining and smoothing chromatograms, simultaneous
zooming
in/out of all selected chromatograms, and creating correlation
chromatograms.
The
ability to export numerous reports in HTML, XLS, and XML formats enables
a
new level of reporting flexibility. Exporting to an XLS file requires
Microsoft
Excel.
The
Data File Viewer/Manager allows viewing, keyword searching, and moving
of
multiple data files via a unique interface.
The
Set Lab Name dialog available via the File menu allows entering of a
laboratory name that will appear on reports.
A
View Methods menu item allows viewing of method parameters without having
to
enter the Instrument Control window.
A
Redraw TIC menu item allows redrawing of the TIC without removing a
selected spectrum window.
An
Annotate Chromatogram with PBM Results menu item labels chromatogram
peaks with the first hit result of a PBM search allowing a graphical
presentation of results.
Linking
of chromatograms is available via the Chromatogram menu when
extended menus are enabled (from the Options menu) and allows
concatenation
of
the selected data files' total ion chromatograms.
Splining
of chromatograms is available via the Chromatogram menu when
extended menus are enabled and enters up to 10 extra data points in
between
real data points depending on the user entered spline factor.
Correlation
Chromatograms can be created that allow comparison of the TIC
with a selected mass spectrum (or library spectra) and display a
"correlation chromatogram" where height is proportional
to the goodness of
the
correlation.
The
Smooth Chromatogram menu item enables Savitsky-Golay smoothing of a
chromatogram.
A
Performance Report can be generated for the current data file which
includes retention time, area, baseline-corrected peak height, peak
width at
baseline, resolution, tailing, Peak-to-Peak S/N, RMS S/N and plates.
A
Display Peak Purity menu item is available to help detect overlapping
(multiple-component)
peaks in a chromatogram and labels each peak with the
number of compounds found in the peak.
Multiple
enhancements were made to the Spectrum menu allowing viewing and
printing of library data.
Calibrate
menu items include the ability to create quant databases from RTL
libraries, reordering of compounds in the calibration table, and printing
calibration curves for particular compounds.
Numerous
enhancements were added to the Tools menu to allow manipulation of
screen databases.
2.
Compatibility
Operating
Systems
English - Supported on Windows 2000 Pro
SP4 & Windows XP Pro SP2
Japanese - Supported on Windows XP Pro SP2
Chinese - Supported on Windows XP Pro SP2
Printers
and Drivers
LaserJet 4020:
These printers are fully tested and are
supported.
The supported drivers are PCL 6
LaserJet 4050 and 4100:
These printers are not tested but inherit
support because
they were tested on
older revisions.
The supported drivers are PCL 5e or PCL 6,
revision 5.02.
LaserJet 2200d and 2300dn:
These printers are not tested but inherit
support because
they were tested on
older revisions.
The supported drivers are Post Script,
revision 5.02.
All DeskJet printers:
These printers are not tested and are not
supported.
____________________________________________
For
the latest drivers, visit the hpq website at
http://welcome.hp.com/country/us/eng/support.html
3.
Instruments Supported
5975 Series MSDs
5973 Series MSDs (GPIB and LAN)
6890 Series GCs (GPIB and LAN)
6850 GC
7683
autosamplers, G1512A & G2612A ALS controllers
G2614A & G2916A autosampler trays
G2880A ALS for the 6850 GC
G2615A Barcode Reader
G1888A,
G1289B, & G1290B Headspace samplers
(with
G2923AA add-on Headspace software)
G3163A & G3164A real-time gas
analyzers
CTC G650x-CTC PAL autosampler
(with
G3384AA add-on CTC Control software)
4.
Instruments Not Supported
All other GCs and MSDs
5.
Software Supported
Windows 2000 Professional SP4
Windows
XP Professional SP2
G1716AA MSD-DRS, A.03.00
G2923AA MSD Headspace Software add-on,
A.01.04
G3384AA CTC Autosampler add-on
G1033A
NIST 05a MS Library
G1035B
Wiley 7th/ NIST 05 Mass Spectral Database
G1036A
NIST Chemical Structures
G1038A
Stan Pesticide Library
G1039B
Pfleger Drug Library
G1049A
RTL Pesticide Library
G1671AA Hazardous Chemical RTL Library
G1672AA Pesticide and Endocrine Disruptor
Library
6.
Software Not Supported
Any other version of windows
========================================================================
G1701DA Revision D.02.00 SP1
CONTENTS
1. New Features
1.1 Hardware
1.2 Electronic Methods (eMethods)
1.3 SIM/Scan Capabilities
1.4 Instrument Control Enhancements
1.5 Data Analysis Enhancements
1.6 Japanese and Chinese Languages
2. Compatibility
3. Instruments Supported
4. Instruments Not Supported
5. Software Supported
6. Software Not Supported
1.
New Features
This
revision adds numerous features to the G1701DA MSD
Productivity Chemstation.
1.1
Hardware
Support
for the new 5975 series MSDs. This
instrument offers
increased mass range to m/z 1050.
Support
for the 6850 GC platform and supported accessories.
The
5973 and 5975 series MSDs chemical ionization (CI) valving and
flow control is now automated.
The
capability to run EI with a CI source has been added.
Automatic
sensing of the installation of the integrated vacuum
gauge option.
1.2
Electronic Methods (eMethods)
To
enable easy sharing and distribution of methods, the capability to
export an MSD ChemStation method into an electronic method
(eMethod) and import an eMethod into an MSD ChemStation
method is provided.
1.3
SIM/Scan Capabilities
A
SIM/Scan acquisition mode has been added for all 5975 instruments.
This
mode is also extended to 5973 instruments with Performance
Electronics
and the 100 mbyte instrument controller (the local
control panel indicates "100 mbyte" when the instrument is
first
powered up).
The
functionality of acquiring SIM and Scan data in the same run is
enabled via synchronous (alternating) SIM/Scan.
The
number of SIM ions and SIM ion groups has been extended from
50 groups of 30 ions to 100 groups of 60 ions. The minimum dwell time
has
been reduced from 10 ms to 5 ms.
A
new SIM group spreadsheet editor has been added to Data Analysis.
1.4
Instrument Control Enhancements
The
Top view has been eliminated and its menus, toolbars and
functionality has been merged into Instrument Control. Now you can
set
up and control your system (including
sequencing) all from
one
easy view.
Two
new toolbar buttons let you tune the MSD and easily access the
maintenance schedule and log.
A
new Help menu item lets you view the IP address(es),
serial numbers
and
revision information for your GC and MS instruments. You can
easily print this information and store it in a logbook or with the
instruments.
The
Sample Log Table (sequence) can be configured to display only
the
column headings that you want to use and more right mouse-click menu
items have been added to simplify editing a sequence.
Print
Method lets you select which sections of a method you want to print.
GC
ChemStation method parameters (excluding 5890 GC) can be imported
into the MSD ChemStation.
1.5
Data Analysis Enhancements
The
new Explorer-style window provides easy navigation of method
and
data files. You have the ability to show or hide the
Explorer
window, and right-click menus are provided for quick data and
method file actions.
Interactive
editing of integration parameters (for the ChemStation Integrator)
is
enabled for easy editing/selecting of the integration parameters and you
can
view the integration result in real time.
Right
mouse-click actions are available in the Chromatogram/Spectrum
windows and can be easily accessed via a toolbar button. (The classic
mouse actions are also available.)
A
spreadsheet-like SIM Parameters Table is provided for easy editing
using right mouse-click actions and can be easily accessed via a
toolbar
button.
QEdit
functionality is improved to allow generating custom and
quantitation reports from QEdit, custom configuring X-axis to
be
shorter so that user does not have to zoom all the time, and quick
review of the integration.
Barcode
(expected or actual) has been added to the report items for
custom reports.
You
can create a Windows metafile from the right mouse-click menu on
the
data variable watch window.
Retention
Time is displayed to 0.xxx minutes in windows and all reports.
You
can double click on a compound in Edit Compound to view the
highlighted compound.
1.6
Japanese and Chinese Languages (SP1)
In
addition to English, the ChemStation software and the online help for
Enhanced
Mode, and the hardware and software manuals are
available in both the Japanese and Simplified Chinese languages.
2. Compatibility
Operating
Systems
Supported on Windows 2000 Professional SP4 and Windows XP
Professional SP2.
Printers
and Drivers
LaserJet 4020:
These printers are fully tested and are
supported.
The supported drivers are PCL 6
LaserJet 4050 and 4100:
These printers are not tested but inherit
support because
they were tested on
older revisions.
The supported drivers are PCL 5e or PCL 6,
revision 5.02.
LaserJet 2200d and 2300dn:
These printers are not tested but inherit
support because
they were tested on
older revisions.
The supported drivers are Post Script,
revision 5.02.
All DeskJet printers:
These printers are not tested and are not
supported.
____________________________________________
For
the latest drivers, visit the hpq website at
http://welcome.hp.com/country/us/eng/support.html
3.
Instruments Supported
Agilent 5975 Series MSDs
Agilent 5973A, 5973N, 5973 inert MSD
Agilent 6890A (GPIB), 6890A (LAN), 6890N
(integrated LAN)
Agilent 6850 GC
Agilent Liquid Samplers
Agilent G1888 Headspace Samplers (with
G2923AA add-on Headspace software)
4.
Instruments Not Supported
All other GC and MSD
5.
Software Supported
Windows 2000 Professional SP4
Windows XP Professional SP2
G1716AA MSD-DRS, A.02.00
G2923AA MSD Headspace Software, A.01.04
G1033A Nist 05 MS Library
G1035B Wiley 7th/ NIST 05 Mass Spectral
Database
G1036A Nist Chemical Structures
G1038A Stan Pesticide Library
G1039B Pfleger Drug Library
G1049A RTL Pesticide Library
6.
Software Not Supported
Any other version of Windows
G1716AA MSD-DRS, A.01.01
G2923AA MSD Headspace Software, A.01.03
========================================================================
G1071DA
Revision D.01.02 SP1
This
revision supports the add-on hooks for the MSD HeadSpace Software
package, G2923AA. No other fixes
were added to this software package.
========================================================================
G1071DA
Revision D.01.02
This
revision supports the Fast Electronics Set added to the 5973 inert
MSD
starting with Serial Number US422xxxxx and available as upgrade
kits for previous 5973A, 5973N, and 5973 inert MS instruments.
Instruments
with Fast Electronics have a Fast Scan mode that is
selected by a "Fast Scanning" checkbox in the SIM/Scan panel
of
Instrument Control. The scan
speeds or Sampling Rates specified
in
the Scan Parameters Panel (0-7) are identical for instruments
with Standard and Fast Electronics.
Instruments
with Fast Electronics have reduced SIM settling
times. The SIM settling time
between SIM ions is the time
required for the electronics and signal to stablize at a new
mass ion setting. The Fast
Electronics require less settling
time and therefore will acquire more points across a
chromatographic peak.
Instruments
with Fast Electronics utilize a more sophisticated
mass domain digital filter.
The new digital filter preserves
the
mass peakshape and signal intensity better than the digital
filter associated with the Standard Electronics. The improvements
in
signal intensity are most noticable at the faster (0,1,2)
scan speeds.
The
Fast Electronics set also includes an improved CI flow
controller module. The
new module provides software ON/OFF
control of the CI Reagent gas.
Recently, Agilent published
a
procedure to acquire EI spectra with a CI ion source. The
ON/OFF
control feature permits CI and EI methods to be used
in
a sequence without any interruptions or prompts to set
the
CI Reagent gas flow.
The
ON/OFF control does not enable the reagent flow to be
controlled, nor does it enable the flow to be changed during
a
sequence. After the MSD is power cycled,
the reagent gas
MUST
be selected by the operator BEFORE the ON/OFF control
will function.
Recipients
of upgrade kits or method developers seeking to
benefit from the improved capabilities of the Fast Electronics
should carefully validate their methods. Users of SIM
methods should ensure that the faster SIM cycle times are
compatible with their integration events.
All
operational modes except Aromatics will see a new menu
item in the Sequence menu that permit the "Classic" sample
log
table editor to be selected.
========================================================================
G1701DA
Revision D.01.00 SP1
This
service pack includes MSD Firmware revision 5.01.63. This
revision is functionally identical to previous revisions, but
it
supports an updated instrument controller card present in
the
5973 inert system.
========================================================================
G1701DA
Revision D.01.00
CONTENTS
1. New Features
2. Compatibility
3. Instruments Supported
4. Instruments Not Supported
5. Software Supported
6. Software Not Supported
1.
New Features
New
toolbar added to the Top Level and an expanded set of tools
added to Data Analysis.
Placing the cursor of the mouse over
a
tool will provide a tool tip.
The
sequence user interface or sample log table has been transformed
into a spreadsheet user interface.
Long
files names are supported. Data file and
method paths can be
up
to 100 characters long. The names of
individual data files and
methods can be up to 50 characters long. If these limits are exceeded
by
renaming or moving of these directories using standard tools of
the
operating system, the total path and file name length could exceed
the
255 character limitation imposed by the file system when methods
are
stored with the data file.
User
Interfaces for selecting or saving files and directories have
been enhanced with browse buttons.
During
sequencing the ABORT button in the status panel has been
changed to Pause. When this is
selected, the sequence will pause
immediately. When the
sequence is started, it will restart the
sequence where it was paused.
Support
for 5973A and 6890A instruments using GPIB has been restored.
Is
it now possible to disable Method Resolution for most changes in
the
6890 configuration.
Tune\Tune
MSD - A new menu item that will tune the currently loaded
tune file according to the criteria specified by the tune
wizard.
This
is the menu item that should be used most of the time if you have
established a tune file name that is not one of the default or
standard
tune file names, such as ATUNE.U, BFB.U etc. The Manual Tune and Vacuum
Control
views of Instrument Control have be merged into a single view, Tune
and
Vacuum Control.
A
Tune Wizard has been provided to simplify the modification of
critera (tune limits, target ratios) used by the tuning algorithms
File\Load
Data File
A
new load data file panel shows 'thumbnail' previews of chromatograms
prior to actual datafile load.
File\List
Header
Will show a new file, ACQMETH.TXT, for data files created by
this revision.
ACQMETH.TXT
contains the instrument control parameters used to create the
data file. Each time a method
is saved, ACQMETH.TXT, is saved with the Method.
ACQMETH.TXT
is in the same format as Print Method.
When a data file is
acquired, ACQMETH.txt is copied from the method directory into the data
file
directory. Most of the time,
ACQMETH.TXT will accurately reflect the
parameters used to acquire the data file. When data is acquired from
instrument control without running the method, changes in the
method
that have not be saved, will not be reflected in ACQMETH.TXT. Similarly,
changes in chromatographic parameters made on the keyboard or in the
driver's user
interface, but not saved in the method, will not be reflected.
File\Select
Printer
New Menu item that Permits one to change the Windows default
printer or specify a particular printer to be used during Run Method. For convenience, there is an option to print
a test page of GC/MS data.
Method\Run
CustomAnalysis
Executes
ONLY the method folder DEUSER.MAC (Enhanced/EQ modes only)
Method\Edit
CustomAnalysis
Allows convenient editing of current method folder DEUSER.MAC
that is run as part of a normal RunMethod.
(Enhanced/EQ modes only)
Spectrum\Find
Mass Spectrum
New menu item that permits one to specify up to six ions or
mass, intensity pairs, and search the data file for the most likely
chromatographic peaks containing those ions.
Tools\Configure
Report Headers (Enhanced/EQ modes only)
New menu item that permits one to specify a custom report header
for the RunMethod reports. Header items
available can be rearranged and/or eliminated from the reports. RunMethod reports include Area%, Library
Search (MS modes only), Quant, and
Drug
Mode Enhancements ( added Revisions D.00.01 )
Intelligent Sequencing enhancements:
Decisions based on Chromatographic
Checks and Calibration Date
'New Batch' keyword with Jump via
Intelligent Sequence decision
'Append' keyword added to chain
batches together
User-naming enabled for batch data folders
AND data files
Position/Run sequence enabled
Requant of calibrators with automated QC
limits determination/update
Automated Retention Time and Ion Ratio
update based on calibrators
New Calibration reports, Sample reports,
and QC summary reports
Post-batch report selection
An improved BOOTP service has replaced the
previous BOOTP program. The
new BOOTP is a true
service and will not interfere with shutting down or
logging off the
computer.
SICL Drivers
The
SICL drivers have been updated to version L.02.01. GPIB instruments
MUST use verision
M.01.01 of the SICL drivers.
These are located on
the G1701DA CD
in the SICL\GPIB Drivers\ directory.
2.
Compatibility
DLLs are not compatible with previous
versions of MSD Chemstation
Virually every file format used by the
software has been updated
to support long
file names. Any programmatic access of
Chemstation
files may have to
be updated.
Printers and Drivers
All DeskJet printers:
These printers are not tested and are not
supported.
LaserJet 4050 and 4100:
These printers are not tested but inherit
support because
they were tested on
older revisions.
The supported drivers are PCL 5e or PCL 6,
revision 5.02.
LaserJet 2200d and 2300dn:
These printers are fully tested and are
supported.
The supported drivers are Post Script
revision 5.02.
____________________________________________
For
the latest drivers, visit the hpq website at
http://welcome.hp.com/country/us/eng/support.html
3.
Instruments Supported
Agilent 5973A, 5973N, 5973 inert MS
Agilent 6890A (GPIB), 6890A (LAN), 6890N
(integrated LAN)
Agilent Liquid Samplers
4. Instruments
Not Supported
All other GC and MSD
5.
Software Supported
G1033A Nist Library
G1036A Nist Chemical Structures
G1035A Wiley Library
G1038A Stan Pesticide Library
G1039B Pfleger Drug Library
G1049A RTL Pesticide Library
6.
Software Not Supported
G1046A Drug Analysis Software
G1047A LC/MS Software
G1048A Protein and Peptide Software
G1032C Environmental Software Revision
C.03.00 or earlier