G1701DA Revision D.03.00 SP1

 

   D.03.00 SP1 is a Service Patch to the D.03.00 revision of the software.

   D.03.00 SP1 fully supports the new ICC firmware for the CTC control.  

   Six (6) software defects which were documented in the PVCS has been fixed

   with this service pack 1 release.

 

========================================================================

 

G1701DA Revision D.03.00

 

   CONTENTS

    

1.  New Features

 

     1.1 Hardware

     1.2 SemiQuant

     1.3 Instrument Control Enhancements

     1.4 Data Analysis Enhancements

     1.5 Enhanced Data Analysis Tools

 

2.  Compatibility

3.  Instruments Supported

4.  Instruments Not Supported

5.  Software Supported

6.  Software Not Supported

    

1. New Features

 

This revision adds numerous features to the G1701DA MSD Productivity ChemStation.

 

1.1 Hardware

 

Support for the new 5975B VL MSD (diffusion pump).

 

Support for the CTC PAL autosampler (available for Enhanced, DrugQuant, and

EnviroQuant modes of operation only).

 

1.2 SemiQuant

 

(Fully supported in Enhanced and Aromatics modes only)

 

A SemiQuant quantitation type has been added to the quantitation parameters

allowing estimation of uncalibrated compound concentration based on a

calibrated compound or internal standard.

 

A new menu item is available via the Calibrate menu and allows conversion

of target compounds into SemiQuant compounds.  This facilitates conversion

from a normal or RTL method into a SemiQuant method.

 

Another new menu item is available via the Calibrate menu that allows

response factor updates of SemiQuant compounds.

 

SemiQuant reports are available to handle the SemiQuant compounds separately

from target compounds to reduce ambiguity within reports.

 

1.3 Instrument Control Enhancements

 

High performance SIM/Scan functionality is now available for the 5975B

Series MSDs.  The MSDs can now utilize 1 millisecond SIM dwell times for SIM

and SIM/Scan modes of operation.

 

Integrated control for the CTC PAL autosampler (with G3384AA add-on CTC

Control software).

 

1.4 Data Analysis Enhancements

 

Easy Extracted Ion Chromatograms (Easy EICS) allows the user to add an EIC

of single ion value or mass range to the chromatogram window by using the

mouse, and the ability to simultaneously display up to 3 separate spectrum

windows. Other features include the ability to save multiple EIC

specification lists for later recall, and the ability to run a multiple

spectra PBM or NIST search. The Easy EIC functions also run in Overlay

Chromatogram view permitting display of multiple EICs and up to 3 spectra

for every data file selected.

 

The AutoSIM setup feature in Data Analysis has been updated to allow

automatic generation of a SIM, Scan, or SIM/Scan acquisition method from an

existing method having a quantitation database.

 

The Update Calibration dialog has been revised to allow update of mass

assignments.

 

The Snapshot feature can now display data being acquired during a SIM, Scan,

or SIM/Scan run.

 

A Reprocessing menu is available that allows a previously run sequence to be

reprocessed inside of Data Analysis.  A sequence may be reprocessed with an

edited Sample Log Table, such as one containing different sample amounts.

 

1.5 Enhanced Data Analysis Tools

 

(Available in Enhanced mode for MS data only)

 

The Analyze Multiple Data Files view can be used to compare the integrity of

samples over time or from different equipment.  The view is primarily for

qualitative investigation of groups of data files.  All of the normal

functions needed to process data files are available plus additional

functions such as splining and smoothing chromatograms, simultaneous zooming

in/out of all selected chromatograms, and creating correlation

chromatograms.

 

The ability to export numerous reports in HTML, XLS, and XML formats enables

a new level of reporting flexibility. Exporting to an XLS file requires

Microsoft Excel.

 

The Data File Viewer/Manager allows viewing, keyword searching, and moving

of multiple data files via a unique interface.

 

The Set Lab Name dialog available via the File menu allows entering of a

laboratory name that will appear on reports.

 

A View Methods menu item allows viewing of method parameters without having

to enter the Instrument Control window.

 

A Redraw TIC menu item allows redrawing of the TIC without removing a

selected spectrum window.

 

An Annotate Chromatogram with PBM Results menu item labels chromatogram

peaks with the first hit result of a PBM search allowing a graphical

presentation of results.

 

Linking of chromatograms is available via the Chromatogram menu when

extended menus are enabled (from the Options menu) and allows concatenation

of the selected data files' total ion chromatograms.

 

Splining of chromatograms is available via the Chromatogram menu when

extended menus are enabled and enters up to 10 extra data points in between

real data points depending on the user entered spline factor.

 

Correlation Chromatograms can be created that allow comparison of the TIC

with a selected mass spectrum (or library spectra) and display a

"correlation chromatogram" where height is proportional to the goodness of

the correlation.

 

The Smooth Chromatogram menu item enables Savitsky-Golay smoothing of a

chromatogram.

 

A Performance Report can be generated for the current data file which

includes retention time, area, baseline-corrected peak height, peak width at

baseline, resolution, tailing, Peak-to-Peak S/N, RMS S/N and plates.

 

A Display Peak Purity menu item is available to help detect overlapping

(multiple-component) peaks in a chromatogram and labels each peak with the

number of compounds found in the peak.

 

Multiple enhancements were made to the Spectrum menu allowing viewing and

printing of library data.

 

Calibrate menu items include the ability to create quant databases from RTL

libraries, reordering of compounds in the calibration table, and printing

calibration curves for particular compounds.

 

Numerous enhancements were added to the Tools menu to allow manipulation of

screen databases.

 

2. Compatibility

 

Operating Systems

 

      English - Supported on Windows 2000 Pro SP4 & Windows XP Pro SP2

      Japanese - Supported on Windows XP Pro SP2

      Chinese - Supported on Windows XP Pro SP2

     

 

Printers and Drivers

 

   LaserJet 4020:

   These printers are fully tested and are supported.

   The supported drivers are PCL 6

 

   LaserJet 4050 and 4100:

   These printers are not tested but inherit support because

   they were tested on older revisions.

   The supported drivers are PCL 5e or PCL 6, revision 5.02.

 

   LaserJet 2200d and 2300dn:

   These printers are not tested but inherit support because

   they were tested on older revisions.

   The supported drivers are Post Script, revision 5.02.

 

   All DeskJet printers:

   These printers are not tested and are not supported.

____________________________________________

 

For the latest drivers, visit the hpq website at

http://welcome.hp.com/country/us/eng/support.html

 

3. Instruments Supported

 

      5975 Series MSDs

      5973 Series MSDs (GPIB and LAN)

      6890 Series GCs (GPIB and LAN)

      6850 GC

      7683 autosamplers, G1512A & G2612A ALS controllers

      G2614A & G2916A autosampler trays

      G2880A ALS for the 6850 GC

      G2615A Barcode Reader

     G1888A, G1289B, & G1290B Headspace samplers

            (with G2923AA add-on Headspace software)

      G3163A & G3164A real-time gas analyzers

      CTC G650x-CTC PAL autosampler

                (with G3384AA add-on CTC Control software)

 

4. Instruments Not Supported

 

      All other GCs and MSDs

 

5. Software Supported

     

      Windows 2000 Professional SP4

     Windows XP Professional SP2

      G1716AA MSD-DRS, A.03.00

      G2923AA MSD Headspace Software add-on, A.01.04

      G3384AA CTC Autosampler add-on

      G1033A NIST 05a MS Library

     G1035B Wiley 7th/ NIST 05 Mass Spectral Database

     G1036A NIST Chemical Structures

     G1038A Stan Pesticide Library

     G1039B Pfleger Drug Library

     G1049A RTL Pesticide Library

      G1671AA Hazardous Chemical RTL Library

      G1672AA Pesticide and Endocrine Disruptor Library

 

6. Software Not Supported

 

      Any other version of windows

 

========================================================================

 

G1701DA Revision D.02.00 SP1

 

   CONTENTS

    

1.  New Features

 

     1.1 Hardware

     1.2 Electronic Methods (eMethods)

     1.3 SIM/Scan Capabilities

     1.4 Instrument Control Enhancements

     1.5 Data Analysis Enhancements

     1.6 Japanese and Chinese Languages

 

2.  Compatibility

3.  Instruments Supported

4.  Instruments Not Supported

5.  Software Supported

6.  Software Not Supported

    

1. New Features

 

This revision adds numerous features to the G1701DA MSD

Productivity Chemstation.

 

1.1 Hardware

 

Support for the new 5975 series MSDs.  This instrument offers

increased mass range to m/z 1050.

 

Support for the 6850 GC platform and supported accessories.

 

The 5973 and 5975 series MSDs chemical ionization (CI) valving and

flow control is now automated.

 

The capability to run EI with a CI source has been added.

 

Automatic sensing of the installation of the integrated vacuum

gauge option.

 

1.2 Electronic Methods (eMethods)

 

To enable easy sharing and distribution of methods, the capability to

export an MSD ChemStation method into an electronic method

(eMethod) and import an eMethod into an MSD ChemStation method is provided.

 

1.3 SIM/Scan Capabilities

 

A SIM/Scan acquisition mode has been added for all 5975 instruments.

This mode is also extended to 5973 instruments with Performance

Electronics and the 100 mbyte instrument controller (the local

control panel indicates "100 mbyte" when the instrument is first

powered up).

 

The functionality of acquiring SIM and Scan data in the same run is

enabled via synchronous (alternating) SIM/Scan.

 

The number of SIM ions and SIM ion groups has been extended from

50 groups of 30 ions to 100 groups of 60 ions.  The minimum dwell time

has been reduced from 10 ms to 5 ms.

 

A new SIM group spreadsheet editor has been added to Data Analysis.

 

1.4 Instrument Control Enhancements

 

The Top view has been eliminated and its menus, toolbars and

functionality has been merged into Instrument Control.  Now you can

set up and control your system  (including sequencing) all from

one easy view.

 

Two new toolbar buttons let you tune the MSD and easily access the

maintenance schedule and log.

 

A new Help menu item lets you view the IP address(es), serial numbers

and revision information for your GC and MS instruments.  You can

easily print this information and store it in a logbook or with the

instruments.

 

The Sample Log Table (sequence) can be configured to display only

the column headings that you want to use and more right mouse-click menu

items have been added to simplify editing a sequence.

 

Print Method lets you select which sections of a method you want to print.

 

GC ChemStation method parameters (excluding 5890 GC) can be imported

into the MSD ChemStation.

 

1.5 Data Analysis Enhancements

 

The new Explorer-style window provides easy navigation of method

and data files. You have the ability to show or hide the

Explorer window, and right-click menus are provided for quick data and

method file actions.

 

Interactive editing of integration parameters (for the ChemStation Integrator)

is enabled for easy editing/selecting of the integration parameters and you

can view the integration result in real time.

 

Right mouse-click actions are available in the Chromatogram/Spectrum

windows and can be easily accessed via a toolbar button. (The classic

mouse actions are also available.)

 

A spreadsheet-like SIM Parameters Table is provided for easy editing

using right mouse-click actions and can be easily accessed via a toolbar

button.

 

QEdit functionality is improved to allow generating custom and

quantitation reports from QEdit, custom configuring X-axis to

be shorter so that user does not have to zoom all the time, and quick

review of the integration.

 

Barcode (expected or actual) has been added to the report items for

custom reports.

 

You can create a Windows metafile from the right mouse-click menu on

the data variable watch window.

 

Retention Time is displayed to 0.xxx minutes in windows and all reports.

 

You can double click on a compound in Edit Compound to view the

highlighted compound.

 

1.6 Japanese and Chinese Languages (SP1)

 

In addition to English, the ChemStation software and the online help for

Enhanced Mode, and the hardware and software manuals are

available in both the Japanese and Simplified Chinese languages.

 

2. Compatibility

 

Operating Systems

 

Supported on Windows 2000 Professional SP4 and Windows XP Professional SP2.

 

Printers and Drivers

 

   LaserJet 4020:

   These printers are fully tested and are supported.

   The supported drivers are PCL 6

 

   LaserJet 4050 and 4100:

   These printers are not tested but inherit support because

   they were tested on older revisions.

   The supported drivers are PCL 5e or PCL 6, revision 5.02.

 

   LaserJet 2200d and 2300dn:

   These printers are not tested but inherit support because

   they were tested on older revisions.

   The supported drivers are Post Script, revision 5.02.

 

   All DeskJet printers:

   These printers are not tested and are not supported.

____________________________________________

 

For the latest drivers, visit the hpq website at

http://welcome.hp.com/country/us/eng/support.html  

    

3. Instruments Supported

 

     Agilent 5975 Series MSDs

     Agilent 5973A, 5973N, 5973 inert MSD

     Agilent 6890A (GPIB), 6890A (LAN), 6890N (integrated LAN)

     Agilent 6850 GC

     Agilent Liquid Samplers

     Agilent G1888 Headspace Samplers (with G2923AA add-on Headspace software)

    

4. Instruments Not Supported

    

     All other GC and MSD

    

5. Software Supported

    

     Windows 2000 Professional SP4

     Windows XP Professional SP2

     G1716AA MSD-DRS, A.02.00

     G2923AA MSD Headspace Software, A.01.04

     G1033A Nist 05 MS Library

     G1035B Wiley 7th/ NIST 05 Mass Spectral Database

     G1036A Nist Chemical Structures

     G1038A Stan Pesticide Library

     G1039B Pfleger Drug Library

     G1049A RTL Pesticide Library

 

6. Software Not Supported

 

     Any other version of Windows

     G1716AA MSD-DRS, A.01.01

     G2923AA MSD Headspace Software, A.01.03

    

========================================================================   

 

G1071DA Revision D.01.02 SP1

 

This revision supports the add-on hooks for the MSD HeadSpace Software

package, G2923AA.  No other fixes were added to this software package.

 

========================================================================

 

G1071DA Revision D.01.02

 

This revision supports the Fast Electronics Set added to the 5973 inert

MSD starting with Serial Number US422xxxxx and available as upgrade

kits for previous 5973A, 5973N, and 5973 inert MS instruments. 

 

Instruments with Fast Electronics have a Fast Scan mode that is

selected by a "Fast Scanning" checkbox in the SIM/Scan panel of

Instrument Control.  The scan speeds or Sampling Rates specified

in the Scan Parameters Panel (0-7) are identical for instruments

with Standard and Fast Electronics.

 

Instruments with Fast Electronics have reduced SIM settling

times.  The SIM settling time between SIM ions is the time

required for the electronics and signal to stablize at a new

mass ion setting.  The Fast Electronics require less settling

time and therefore will acquire more points across a

chromatographic peak.

 

Instruments with Fast Electronics utilize a more sophisticated

mass domain digital filter.  The new digital filter preserves

the mass peakshape and signal intensity better than the digital

filter associated with the Standard Electronics.  The improvements

in signal intensity are most noticable at the faster (0,1,2)

scan speeds.

 

The Fast Electronics set also includes an improved CI flow

controller module.  The new module provides software ON/OFF

control of the CI Reagent gas.  Recently, Agilent published

a procedure to acquire EI spectra with a CI ion source.  The

ON/OFF control feature permits CI and EI methods to be used

in a sequence without any interruptions or prompts to set

the CI Reagent gas flow.

 

The ON/OFF control does not enable the reagent flow to be

controlled, nor does it enable the flow to be changed during

a sequence.  After the MSD is power cycled, the reagent gas

MUST be selected by the operator BEFORE the ON/OFF control

will function.

 

Recipients of upgrade kits or method developers seeking to

benefit from the improved capabilities of the Fast Electronics

should carefully validate their methods.  Users of SIM

methods should ensure that the faster SIM cycle times are

compatible with their integration events.

 

All operational modes except Aromatics will see a new menu

item in the Sequence menu that permit the "Classic" sample

log table editor to be selected.

 

========================================================================

 

G1701DA Revision D.01.00 SP1

 

This service pack includes MSD Firmware revision 5.01.63.  This

revision is functionally identical to previous revisions, but

it supports an updated instrument controller card present in

the 5973 inert system.

 

========================================================================

 

G1701DA Revision D.01.00

 

 

   CONTENTS

    

1.  New Features

    

2.  Compatibility

    

3.  Instruments Supported

    

4.  Instruments Not Supported

    

5.  Software Supported

    

6.  Software Not Supported

 

    

    

1. New Features

 

New toolbar added to the Top Level and an expanded set of tools

added to Data Analysis.  Placing the cursor of the mouse over

a tool will provide a tool tip.

 

The sequence user interface or sample log table has been transformed

into a spreadsheet user interface.

 

Long files names are supported.  Data file and method paths can be

up to 100 characters long.  The names of individual data files and

methods can be up to 50 characters long.  If these limits are exceeded

by renaming or moving of these directories using standard tools of

the operating system, the total path and file name length could exceed

the 255 character limitation imposed by the file system when methods

are stored with the data file.

 

User Interfaces for selecting or saving files and directories have

been enhanced with browse buttons.

 

During sequencing the ABORT button in the status panel has been

changed to Pause.  When this is selected, the sequence will pause

immediately.  When the sequence is started, it will restart the

sequence where it was paused.

 

Support for 5973A and 6890A instruments using GPIB has been restored.

  

Is it now possible to disable Method Resolution for most changes in

the 6890 configuration.

 

 

Tune\Tune MSD - A new menu item that will tune the currently loaded

tune file according to the criteria specified by the tune wizard. 

This is the menu item that should be used most of the time if you have

established a tune file name that is not one of the default or standard

tune file names, such as ATUNE.U, BFB.U etc.  The Manual Tune and Vacuum

Control views of Instrument Control have be merged into a single view, Tune

and Vacuum Control.

 

A Tune Wizard has been provided to simplify the modification of

critera (tune limits, target ratios) used by the tuning algorithms

  

File\Load Data File

 

A new load data file panel shows 'thumbnail' previews of chromatograms

prior to actual datafile load.

 

File\List Header

 

Will show a new file, ACQMETH.TXT, for data files created by this revision. 

ACQMETH.TXT contains the instrument control parameters used to create the

data file.  Each time a method is saved, ACQMETH.TXT, is saved with the Method. 

ACQMETH.TXT is in the same format as Print Method.  When a data file is

acquired, ACQMETH.txt is copied from the method directory into the data file

directory.  Most of the time, ACQMETH.TXT will accurately reflect the

parameters used to acquire the data file.  When data is acquired from

instrument control without running the method, changes in the method

that have not be saved, will not be reflected in ACQMETH.TXT.  Similarly,

changes in chromatographic parameters made on the keyboard or in the

 driver's user interface, but not saved in the method, will not be reflected.

 

File\Select Printer

 

New Menu item that Permits one to change the Windows default printer or specify a particular printer to be used during Run Method.  For convenience, there is an option to print a test page of GC/MS data.

 

Method\Run CustomAnalysis

 

Executes ONLY the method folder DEUSER.MAC (Enhanced/EQ modes only)

 

Method\Edit CustomAnalysis

 

Allows convenient editing of current method folder DEUSER.MAC that is run as part of a normal RunMethod.  (Enhanced/EQ modes only)

 

Spectrum\Find Mass Spectrum

 

New menu item that permits one to specify up to six ions or mass, intensity pairs, and search the data file for the most likely chromatographic peaks containing those ions.

 

Tools\Configure Report Headers (Enhanced/EQ modes only)

 

New menu item that permits one to specify a custom report header for the RunMethod reports.  Header items available can be rearranged and/or eliminated from the reports.  RunMethod reports include Area%, Library Search (MS modes only), Quant, and Non-Target Peaks (MS modes only).  Generic Data and Method header formats are also included for non-RunMethod reports such as Initial Calibration, List Compounds, Tune check, etc.

 

 

Drug Mode Enhancements ( added Revisions D.00.01 )

      Intelligent Sequencing enhancements:

         Decisions based on Chromatographic Checks and Calibration Date

         'New Batch' keyword with Jump via Intelligent Sequence decision

         'Append' keyword added to chain batches together

         User-naming enabled for batch data folders AND data files

         Position/Run sequence enabled

      Requant of calibrators with automated QC limits determination/update

      Automated Retention Time and Ion Ratio update based on calibrators

      New Calibration reports, Sample reports, and QC summary reports

      Post-batch report selection

 

   An improved BOOTP service has replaced the previous BOOTP program.  The

   new BOOTP is a true service and will not interfere with shutting down or

   logging off the computer.

 

   SICL Drivers

      The SICL drivers have been updated to version L.02.01.  GPIB instruments

      MUST use verision M.01.01 of the SICL drivers.  These are located on

      the G1701DA CD in the SICL\GPIB Drivers\ directory.   

 

 

2. Compatibility

    

   DLLs are not compatible with previous versions of MSD Chemstation

 

   Virually every file format used by the software has been updated

   to support long file names.  Any programmatic access of Chemstation

   files may have to be updated. 

 

   Printers and Drivers

 

   All DeskJet printers:

   These printers are not tested and are not supported.

 

   LaserJet 4050 and 4100:

   These printers are not tested but inherit support because

   they were tested on older revisions.

   The supported drivers are PCL 5e or PCL 6, revision 5.02.

 

   LaserJet 2200d and 2300dn:

   These printers are fully tested and are supported.

   The supported drivers are Post Script revision 5.02.

 

____________________________________________

 

For the latest drivers, visit the hpq website at

http://welcome.hp.com/country/us/eng/support.html  

    

3. Instruments Supported

    

     Agilent 5973A, 5973N, 5973 inert MS

     Agilent 6890A (GPIB), 6890A (LAN), 6890N (integrated LAN)

     Agilent Liquid Samplers

    

4. Instruments Not Supported

    

     All other GC and MSD

    

5. Software Supported

    

     G1033A Nist Library

     G1036A Nist Chemical Structures

     G1035A Wiley Library

     G1038A Stan Pesticide Library

     G1039B Pfleger Drug Library

     G1049A RTL Pesticide Library 

    

6. Software Not Supported

     G1046A Drug Analysis Software

     G1047A LC/MS Software

     G1048A Protein and Peptide Software

     G1032C Environmental Software Revision C.03.00 or earlier